beautypg.com

Limiting minimum frequency, Related parameters, Limiting minimum frequency -31 – Yaskawa G7 Drive User Manual

Page 248

background image

Speed Limit (Frequency Reference Limit Function)

6-

31

‹

Limiting Minimum Frequency

If you do not want the motor to rotate at below a given frequency, use parameters d2-02 or d2-03.
There are two methods of limiting the minimum frequency, as follows:

Adjust the minimum level for all frequencies.

Adjust the minimum level for the master speed frequency (i.e., the lower levels of the jog frequency, multi-
step speed frequency, and auxiliary frequency will not be adjusted).

„

Related Parameters

„

Adjusting Frequency Lower Limit Using an Analog Input

If you set parameter H3-09 (Multi-function Analog Input Terminal A2 Function Selection) or H3-05 (Multi-
function Analog Input Terminal A3 Function Selection) to 9 (output frequency lower level), you can adjust the
frequency lower level using the terminal A2 input level.

Fig 6.30 Output Frequency Lower Level for Multi-function Analog Input

Parameter

Number

Name

Description

Setting
Range

Factory

Setting

Change

during

Operation

Control Methods

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

d2-02

Frequency
Reference
Lower Limit

Determines maximum frequency
reference, set as a percentage of
maximum output frequency
(E1-04). If the frequency
reference is above this value,
actual Drive speed will be limited
to this value. This parameter
applies to all frequency reference
sources.

0.0

to

110.0

0.0%

No

A

A

A

A

A

Ref Lower
Limit

d2-03

Master Speed
Reference
Lower Limit

Determines maximum frequency
reference, set as a percentage of
maximum output frequency (E1-
04). If the frequency reference is
above this value, actual Drive
speed will be limited to this value.
This parameter applies to all
frequency reference sources.

0.0

to

110.0

0.0%

No

A

A

A

A

A

Ref1 Lower
Limit

INFO

If parameter d2-02 and terminal A2 output frequency lower level have been set at the same time, the larger
set value will become the frequency lower limit.

Output frequency lower level

0 V

(4 mA)

Multi-function analog input
terminal A2 or A3 input level

10 V

(20 mA)

Max. output frequency

E1-04