beautypg.com

Yaskawa J7 Drive User Manual

Page 81

background image

6-8

Constant
No.

Name

Description

U-01

Frequency reference

Hz

Frequency reference can be monitored.

(FREF)

(Same as FREF)

U-02

Output frequency

Hz

Output frequency can be monitored.

(FOUT)

(Same as FOUT)

U-03

Output current

Hz

Output current can be monitored.

(IOUT)

(Same as IOUT)

U-04

Output voltage

V

Output voltage can be monitored.

U-05

DC voltage

V

Main circuit DC voltage can be monitored.

U-06

Input terminal status

Input terminal status can be monitored.
(see paragraph 4.4)

U-07

Output terminal status

Output terminal status can be monitored.
(see paragraph 4.4)

U-09

Fault history

Last four fault history is displayed.

(last 4 faults)

(see paragraph 4.4)

U-10

Software No.

Software No. can be checked.

U-15

Data reception error

See Table below

• Monitoring

Following items can be monitored by U-constants

U-15

Description

Data

0

CRC Error

1

Data Length Error

2

Not Used

3

Parity Error

4

Overrun Error

5

Framing Error

6

Time out Error