2 startup procedure, Startup procedure -2, Table 2-1. startup procedure – Yaskawa J7 Drive User Manual

Page 27

background image

2-2

IMPORTANT: 2-wire or 3-wire sequence selection must be made prior to any other adjustments
(Parameter

n01

).

2.2 STARTUP PROCEDURE

DIGITAL OPERATOR

DESCRIPTION

KEY SEQUENCE

DISPLAY

Table 2-1. Startup Procedure

Set motor rated current.

(This can be obtained from
the nameplate of the motor.)

Press

key until the

LED is lit

on the digital operator.

Press and hold

until n32 is

displayed on the digital operator.

Then press

.

Use the

&

keys until the

number in the display matches the motor
rated current.

Then press

.

DATA

ENTER

V

V

DATA

ENTER

V

PRGM

DSPL

Set the V/f pattern.

Parameters n09 through n15
set the V/f pattern. Table 5-4
in section 5.26 lists
recommended V/f patterns.
The numbers in parentheses
shown in the example below
are for a 460V / 60 Hz
variable torque application
(fan or pump).

Set Parameter n09-

Maximum output frequency.

(60.0 Hz)

Press and hold

until n09 is displayed

on the digital operator.

V

PRGM

PRGM

PRGM

PRGM

PRGM

Then press

.

DATA

ENTER

Then press

.

DATA

ENTER

Use the

&

keys until the

desired number is in the display.

V

V

(1)

(1)

(1)

PRGM