beautypg.com

Yaskawa J7 Drive User Manual

Page 78

background image

6-5

Fault Display

Digital

RUN (Green)

Drive

Explanation

Causes and

Operator

ALARM (Red)

Status

Corrective Actions

UV2 (Control power

Cycle power.

supply fault)

If the fault remains.

Voltage fault of control

replace the drive.

power supply is detected.

OH (Cooling fin overheat)

• Excessive load

Temperature rise

• Improper V/f pattern

because of drive

setting

overload operation or

• Insufficient accel time

intake air temperature

if the fault occurs

rise.

during acceleration

• Intake air temperature

exceeding 122°F (50°C)

Check the following:
• Load size
• V/f pattern setting

(parameters n09 to n15)

• Intake air temperature.

OL1 (Motor overload)

• Check the load size or

Protective

Motor overload

V/f pattern setting

Operation.

protection operates by

(parameters n09 to n15)

Output is

built-in electronic thermal

• Set the motor rated

shut OFF

overload relay.

current shown on the

and motor

nameplate in parameter

coasts to

n32.

a stop.

OL2 (Drive overload)

• Check the load size or

Drive overload

V/f pattern setting

protection operates by

(parameters n09 to n15)

built-in electronic thermal

• Check the drive

overload relay.

capacity.

OL3 (Overtorque detection)

Check the driven

Drive output current

machine and correct the

exceeded the preset value in

cause of the fault, or

parameter n60.

increase the value of
parameter n60 up to the

When overtorque is

highest value allowed for

detected, drive performs

the machine.

operation according to the
preset setting of parameter
n59.

Table 6-2. Fault Displays and Corrective Actions - Continued