Fault Display

Digital

RUN (Green)

Drive

Explanation

Causes and

Operator

ALARM (Red)

Status

Corrective Actions

CPF-05

Cycle power.

A/D converter fault is

If the fault remains,

detected.

replace the drive.

CPF-06

Remove power to the

Option card connecting fault

drive.
Check the connection

Protective

of the digital operator.

Operation.

CPF-07

Cycle power after checking

Output is

Operator control circuit

the digital operator is

shut OFF

(EEPROM or A/D

securely mounted.

and motor

converter) fault

If the fault remains,

coasts to

replace the digital operator

a stop.

or drive.

OPR (Operator

Cycle power.

connecting fault)

If the fault remains,
replace the drive.

CE (MODBUS

Check the communication

communications fault)

devices or communication
signals.

STP (Fast stop)

Check the external circuit

The drive stops

(sequence).

according to parameter
n04 after receiving the
emergency stop fault
signal.

Stops
according to

• Insufficient power

Check the following:

parameter.

supply voltage

• Power supply voltage

• Control power supply

• Main circuit power

fault

supply wiring is

• Hardware fault

connected.

• Terminal screws are

securely tightened.

• Control sequence.
Replace the drive.

Table 6-2. Fault Displays and Corrective Actions - Continued