Caution, Continued 1.4 electrical installation – Yaskawa J7 Drive User Manual
Page 23

1-11
Continued
1.4 ELECTRICAL INSTALLATION
L1 ( R )
L2 ( S )
L3 ( T )
FREQUENCY
SETTING POWER SUPPLY
(+12V, 20mA) (See Note 2)
REFERENCE
FREQUENCY
SETTING
POT
(0 to 10V, 20K
Ω
/
4 to 20mA, 250
Ω
)
MIN
SW7
SW8
PNP
NPN
V
I
MAX
–
+2
+1
AC
MOTOR
T1 ( U )
T2 ( V )
T3 ( W )
MCCB
L1
L2
L3
S1
FORWARD
RUN/STOP
LOGIC
COMMON
TERMINAL
FREQUENCY
REF.
3-PHASE
POWER SUPPLY
(Use L1 (R)
and L2 (S) for
single-phase input)
(Note that drive must
be derated by 50%)
MULTI-FUNCTION
OUTPUT CONTACT
250VAC, 1A OR LESS
30VDC, 1A OR LESS
SHIELD
CONNECTION
ANALOG MONITOR
REVERSE
RUN/STOP
S2
S4
S3
S5
FAULT
RESET
EXTERNAL
FAULT
MULTI-STEP
SPEED REF
A
SC
FC
OV
FS
FR
AM
AC
FM
ANALOG OUTPUT
MONITOR 0 to +10VDC, 2mA (8 Bits)
OUTPUT
FREQUENCY
MULTI-FUNCTION
CONTACT INPUT
MA
MB
MC
FAULT
FOR DC REACTOR
(See Note 6)
(See Note 5)
*
*
*
(See Note 7)
(See Note 5)
(See Note 4)
(See Note 1)
1RH
MANUAL
SPEED
2K
Ω
0-10VDC
or
4-20mA
1OL (See Note 3)
*
*
*
*
–
+
1OL
See
Note 3)
1R
2K
Ω
FIG. 1-5 (305)
Figure 1-5. Standard Connections (2-Wire Control)
(Parameter n01 set to “10”)
H. Inspection.
After wiring is complete, verify that:
All wiring is correctly installed.
Excess screws and wire clippings are removed from inside of unit.
Screws are securely tightened.
Exposed wire does not contact other wiring or terminals.
CAUTION
If a FWD or REV run command is given from the control
circuit terminal when the operation method selection
function ( n02 ) is set to “ 1 ” and the “LO/RE” selection
is set to “RE”, the motor will start automatically as soon
as power is applied to the main circuit.