27 copy function, Copy function -38 – Yaskawa J7 Drive User Manual
Page 73

5-38
The optional Remote Digital Operator can be used to store (upload) parameters from a drive, which
can then be copied (downloaded) to another drive. These parameters are stored in EEPROM in the
Digital Operator. The Copy Function is possible only for drives of the same type (i.e. from one J7 to
another, but not from a J7 to a V7 or vice versa), and voltage rating (230V drive or 460V drive). In
addition, the following parameters cannot be copied:
5.27 COPY FUNCTION
Parameter No.
Parameter Name
n09 to n15
V/f Settings
n32
Motor Rated Current
n46
Carrier Frequency
n64
Motor Rated Slip
n65
Motor No-load Current
n76
: Parameter Copy Function Selection
Ex :
Factory Setting: rdy
Setting
Description
rdy
Drive is ready to use Copy Function
rEd
Read (or upload) all parameters from the drive and store them in the Digital Operator
Cpy
Copy (or download) all parameters stored in the Digital Operator to the drive
vFy
Verify that parameters stored in the Digital Operator and the drive are the same
vA
Displays the voltage and kW rating of the drive whose parameters are stored in the
Digital Operator
Sno
Displays the software number of the drive whose parameters are stored in the
Digital Operator
n77
: Parameter Copy Access Selection
Factory Setting: 0
Range: 0 or 1
Setting
Description
0
Copying Disabled
1
Copying Allowed
The Copy Function can be enabled or disabled using parameter n77 – parameters cannot be
uploaded or downloaded when this parameter is disabled (n77 = 0), preventing the accidental
overwriting of parameters stored in either the Digital Operator or the Drive.
If n77 = 0 and an upload or download is attempted (n76 = rEd or Cpy), a “PrE” error message will
blink on the Digital Operator display – press DSPL or DATA/ENTER to clear the message.
For more detailed information on the use of the Copy Function, please visit our website at
www.drives.com.