5-10

The Drive allows selection of up to eleven frequency references. One is an analog input (terminal
FR), eight are digital presets (selected with multi-function inputs), one is a jog input, and one is via
serial communications (MODBUS).

A.

Frequency Reference via Analog Input

In order to set the Drive so the frequency reference comes from the analog input, set parameter

n03

as shown in the table below:

(1)

SW8 can be found just above the control circuit terminals. The switch connects a 250

resistor from terminal FR to FC

when set to the “I” position (to the right). NOTE: All power must be removed from the Drive before SW8 can be set.

B.

Frequency Reference via Digital Presets

In order to set the Drive so the frequency reference comes from the digital presets, the following
parameters need to be set:

Depending upon how many preset references are required determines the actual settings of

n36

thru

n39

. Several examples are listed below.

PARAMETER

SETTING

DESCRIPTION

n21

User

thru

Set

Eight Frequency References, plus jog Frequency

n29

n36

6, 7,

Sets the multi-function inputs so selection of the various references is

thru

and/or 8

possible with contact closures.

n39

PARAMETER

SETTING

DESCRIPTION

2

Sets terminal FR for a voltage input (0 to 10V) Set SW8 to “V” (Off)

(1)

n03

3

Sets terminal FR for a current input (4 to 20mA) Set SW8 to “I”

(1)

4

Sets terminal FR for a current input (0 to 20mA) Set SW8 to “I”

(1)