beautypg.com

Adapting the limit values, 1 0 load monit o ri ng (option) – HEIDENHAIN SW 54843x-03 User Manual

Page 127

background image

HEIDENHAIN MANUALplus 620

127

3.1

0

Load monit

o

ri

ng (option)

Adapting the limit values

After successful reference machining, the control uses the reference
values and the predefined factors specified in the machine parameters
to calculate the limit values.

You can adapt the calculated limit values as required for the
subsequent production.

To display limit values, select the menu View > Edit load data—the
control opens the "Set load data" form

Check the limit values

If required, adapt the parameters PG1, PG2 or WGF

ADAPT LIMIT VALUES

Be sure to adapt the correct limit values. First, press the
Next zone and Next axis soft keys to select the form
containing the limit values you want to change! As an
alternative, you can use the selection lists of the ZO and
AX parameters to select the correct form. Save the
changes separately for each axis by pressing the Save soft
key!

Reference machining does not have to be repeated after
adapting the limit values. You can continue production
with the adapted limit values.