beautypg.com

Calibrating the tool touch probe, 5 mac h ine set u p – HEIDENHAIN SW 54843x-03 User Manual

Page 103

background image

HEIDENHAIN MANUALplus 620

103

3.5 Mac

h

ine set

u

p

Calibrating the tool touch probe

The "Calibrate the tool touch probe" function enables you to determine
the exact position values of the tool touch probe.

Insert an exactly measured tool or reference tool

Select Setting up

Select touch probe

Select tool touch probe

Pre-position the tool for the first direction of measurement

Set the positive or negative traverse direction

Press the soft key for this direction (e.g. –Z direction)

Press Cycle START. The tool moves in the direction
of measurement. The position of the touch probe is
measured and saved when the tool touch probe
releases a trigger signal. The tool returns to the
starting point.

Press the "Back" soft key to terminate the calibration
process. The calibration values measured are saved,
or

Pre-position the tool for the next measuring direction and repeat the
procedure (max. 4 measuring directions)

MEASURING THE TOUCH PROBE POSITION