beautypg.com

Checking the reference values, 1 0 load monit o ri ng (option) – HEIDENHAIN SW 54843x-03 User Manual

Page 125

background image

HEIDENHAIN MANUALplus 620

125

3.1

0

Load monit

o

ri

ng (option)

Checking the reference values

After the successful completion of reference machining, check the
determined reference values.

Meanings of the values:

Utilization: Determined drive torque relative to the rated torque of
the drive in [%]

Total utilization: Sum of the utilization values in the monitoring zone
in [%*ms]

To display the reference values, select the menu View > Edit load
data
. The control opens the "Set load data" form containing the
parameters listed below. In addition, the determined values are
displayed as a bar graph.

The load monitoring function compares current utilization
values with limit values. For proper comparison, the
reference values for utilization must not be too low. Check
the determined values and, if required, remove monitored
axes with a utilization rate of less than 5 % from the
monitoring zone.

OPEN REFERENCE VALUES

Parameters
ZO

Number of the monitoring zone

AX

Monitored axis

CH

Selected channel

T

Tool pocket of the active tool in the monitoring zone

ID

Name of the active tool in the monitoring zone

P

Maximum utilization during reference machining

PA

Maximum utilization during the current machining
operation

PG1

Utilization limit 1

PG2

Utilization limit 2

W

Total utilization during reference machining

WA

Total utilization during the current machining operation

WGF

Factor for the total utilization limit