Visara FEP-4600 Installation User Manual
Page 10

Chapter 1. Installation
1-2
707119-001
5.
Connect to the platform with a web browser to finish the configuration.
If multiple FEP-4600 platforms are to be interconnected, you may elect to bring them up
one at a time, or through editing of the FEP4600.ini file on each platform, bring them up
as a group. Gateway circuits requiring an ESCON half-circuit on one platform and a
downstream connection on another platform require that both units are powered up and
communicating with each other to make the configuration.
Chassis Installation
Tools needed:
1. Phillips Screw Driver
2. Antistatic Strap
Installing Chassis Rails:
Please make sure that the chassis covers and chassis rails are installed on the chassis
before you install the chassis into the rack.
To avoid personal injury and property damage, please follow all the safety steps listed
below.
Before installing the chassis rails:
1. Enclose the chassis with chassis covers.
2. Unplug the AC power cord(s).
3. Remove all external devices and connectors.
Procedures to install chassis rails:
1. Included in the shipping package is a pair of rail assemblies. In each rail
assembly, locate the inner rail and the outer rail.
2. Press the locking tab to release the inner rail from its locking position and pull out
the inner rail from the rail assembly. (The inner rails are to be attached to the
chassis and the outer rails are to be installed in the rack.)
3. Locate the five rail buttons and each side of the chassis and locate the five
corresponding holes on each of the inners rails.
(Please note that one end of the hole is larger than the other end of the hole.)