Super Systems 20PQ User Manual
Page 39
![background image](https://www.manualsdir.com/files/806348/content/doc039.png)
35
CnF. 2
- Filter on auxiliary input - [C.d13]
This parameter is available only when auxiliary input is
configured
Ranges: from 0 (no filter) to 8 seconds.
NOTE: this is a first order digital filter applied to the measured
value made by the auxiliary input.
General note about configuration group 1
Exiting from the configuration group 1 the instrument automati-
cally verifies the programmed span for the linear input.
If it is wrong, the device will show:
Push the FUNC pushbutton more times until the "ñ.In.L" [C.d05]
or "ñ.In.H" [C.d06] are displayed and modify their value in order
to respect the minimum read-out span (see NOTE 2 of the
"ñ.In.H" [C.d06] parameter).
CONFIGURATION GROUP 2 [C.Exx]
OUTPUTS CONFIGURATION
- OUT 1 function - [C.E01]
Range: nonE = Output not used
ñAin
= Time proportional main control output
SECn = Time proportional secondary control output
ALr.1 = Alarm 1 output
Eun.1 = Event 1 output
NOTE: for Event description see "Event 1
function" [C.H.09] parameter.