Super Systems AC20 Quick Start User Manual
Ac20 quick start instructions, Keyboard description
Super Systems Inc.
1
1 (800)-666-4330
Cincinnati, OH 45241
Fax: (513) 772-0060
//Ssio1/main/.ssimanuals/ac20qs
www.supersystems.com
Keyboard Description:
MENU Is used to select a parameter group
FUNC: when the instrument is in Normal Display Mode changes the indication on
the lower display (default display is % of control output)
MAN: When the instrument is in Normal Display Mode, pushing MAN for more
than one second enables or disables the manual function
Press
⇑⇑
Key during parameter modification to increase the value of the selected
parameter.
Press
⇑⇑
Key during MANUAL Mode to increase the output value
Press
⇓⇓
Key During parameter modification to decrease the value of the
selected parameter.
Press
⇓⇓
Key during MANUAL Mode to decrease the output value
Press
TST+MAN Hold TST and then press MAN button to start the Burnoff
function.
*
Press
TST+FUNC Hold TST, then press
FUNC Button to start the Probetest
function.
∗
Test + MENU Are used to start the lamp test function (the command is accepted
when push-buttons are kept depressed for more that 5 seconds and the
instrument is in normal display mode)
Press
TEST + FUNC during parameter modification to increase/decrease the
value under modification to higher rate.
Press
TEST+MAN
during parameter modification to jump to the max or min
programmable value.
∗
Two conditions apply: First, the burnoff function must be configured and second, it must be at
least 10 minutes from the last burnoff, for the test to st
art
SSi