beautypg.com

Super Systems 20PQ User Manual

Page 104

background image

100

Gr. Hd

- Relative gain of the secondary output
calculated by SMART algorithm - [r.M05]

This parameter is available only when smart function is
configured (“Sñ.Fn” [C.G01] = “Enb”) and a secondary control
output (without split range) is configured.
Upper display: Gr.Hd
Lower display: rG.CL
Range: OFF = Smart algorithm does not calculate “r.Gn”

[r.d06] value.

On

= Smart algorithm calculates “r.Gn” [r.d06] value.

- Hidden group default data loading - [r.M06]

Upper display: Gr.Hd
Lower display: dFLt.
Range: OFF = No loading data

On = loading data

PROGRAMMER MODE

When the instrument is in programmer mode the PRG LED is lit.
The following states are possible.

STAND-BY.
It is a transition state where the instrument is first placed when:
- it is switched from CONTROLLER to PROGRAMMER mode;
- a program execution is ended.
The upper display shows the measured variable and the lower
display shows the set point (NORMAL DISPLAY mode).
The instrument is operating as controller using the set point
used in controller mode (if the transfert from controller mode to
programmer mode has been required) or the set point
programmed for the end of the last executed pattern.
In STAND-BY mode it is possible:
1) to start a program execution;
2) to EDIT a program;
3) to modify run time parameters;
4) to revert to the CONTROLLER mode;
5) to enter in the MANUAL mode.

XKP-1-C2.p65

10/30/01, 9:37 AM

100