Smithco Envizio Pro Installation & Operation Manual User Manual
Page 84

Chapter 6
74
Envizio Pro and Envizio Pro II Installation and Operation Manual
Display Options. Additional displays may be enabled or disabled with the options at the lower portion of the
screen.
The following screen features are available on this screen:
•
On-Screen Rate Bump buttons - While in CAN product control mode, Rate Bump buttons can be used to
increase or decrease the application rate of the selected product. Select the ‘Enable On-Screen Rate Bump
Buttons’ option to show these buttons on the Guidance screen.
When the product is in automatic mode, the Rate Bump buttons will increase or decrease the target rates
for the selected product. When in Manual mode, the Rate Bump buttons increase or decrease the actual
application rate.
Note:
The ‘INC/DEC’ switch on the CAN Switch Box offers the same functionality as the on-screen rate
bump buttons in both the manual and automatic control modes.
•
On-Screen Pressure or Fan Speed display - If an optional pressure transducer or fan speed sensor have
been installed and configured, the field computer can display the monitored values on the Guidance screen.
Select the ‘Enable On-Screen Pressure or Fan Spd’ option to display the Pressure for liquid products or the
Fan Speed for granular products.
•
Enable On-Screen Option - Select the ‘Enable On-Screen Option’ to select an optional second information
display on the Guidance screen.
Select the ‘Pressure #2’ option to display pressure from a second optional transducer. The ‘Pump RPM’
option may be enabled to display the RPM of the corresponding injection pump.