beautypg.com

Smithco Envizio Pro Installation & Operation Manual User Manual

Page 192

background image

Appendix A

182

Envizio Pro and Envizio Pro II Installation and Operation Manual

Thus, as the volume per minute increases, the following tier switching should occur:

10 GPM [37.8 L/min] increasing to 20 GPM [75.7 L/min] = only tier 1 enabled

20 GPM [75.7 L/min] increasing to 30 GPM [113.6 L/min] = only tier 2 enabled

30 GPM [113.6 L/min] increasing to maximum flow rate = tier 1 and tier 2 enabled

Note:

Percent Tier Disable only affects tier switching when the required volume per minute is
decreasing.

As rates begin to decrease from maximum, the Percent Tier Disable value is figured in. Thus, using the Tier 2
Max of 30 GPM [113.6 L/min] previously calculated and with the Percent Tier Disable set to 10%, tier 1 and 2
will switch to only tier 2 when the target rate decreases to 27 GPM [102.2 L/min].

So, for rates in gallons per minute:
30 GPM – (10% of 30 GPM) = 30 GPM – 3 GPM = 27 GPM

or, for rates in liters per minute:
113.6 L/min – (10% of 113.6 L/min) = 113.6 L/min – 11.3 L/min = 102.3 L/min

In operation, as the volume per minute decreases, the following boom tier switching should occur.

Maximum flow rate decreasing to 27 GPM [102.2 L/min] = tier 1 and tier 2 enabled

27 GPM [102.2 L/min] decreasing to 18 GPM [68.1 L/min] = only tier 2 enabled

18 GPM [68.1 L/min] decreasing to 10 GPM [37.8 L/min] = only tier 1 enabled

1

2

1

2

1

2

10 - 20 GPM

20 - 30 GPM

30 GPM- Max. Flow

37.8 - 75.7 L/min

75.7 - 113.6 L/min

113.6 L/min - Max. Flow

1

2

1

2

1

2

Max. Flow - 27 GPM

27 - 18 GPM

18 - 10 GPM

Max. Flow - 102.2 L/min

102.2 - 68.1 L/min

68.1 - 37.8 L/min