Application type, Speed – Smithco Envizio Pro Installation & Operation Manual User Manual
Page 109

7
Manual No. 016-0171-148
99
Tools Menu
The Product Control Configuration screen contains several of the calibration numbers which the field computer
requires to provide product control.
Access the product control configuration to adjust the following settings for the product control system:
•
Application type
•
Speed sensor type and cal
•
Valve type and cal
•
Product control node cal values
•
Volume and area settings
•
Feature settings
•
Alarm settings
•
Section assignments
Application Type
The Application button displays the current application type. Touch the application area to select Liquid, Gran1
(single bed, single encoder), Gran2 (dual bed, single encoder) or Gran3 (dual bed, dual encoder) for the
selected product.
Depending on the product node, an option for spinner or injection control may also be available. If the control
system detects an injection node, the application types will be limited to liquid injection or granular injection.
Speed
The Speed button displays the current speed calibration value. Touch the Speed button to display the Speed
Cal screen.
Sensor Type
Select the type of speed sensor to be used with the Envizio Pro or Envizio Pro II control system.