beautypg.com

Accuboom™ configuration – Smithco Envizio Pro Installation & Operation Manual User Manual

Page 202

background image

Appendix C

192

Envizio Pro and Envizio Pro II Installation and Operation Manual

AccuBoom™ Configuration

Use the following procedure to calibrate the AccuBoom turn-on and turn-off look-ahead values to the Bogballe
spreader:

Note:

The turn-on/turn-off look-ahead values may be adjusted after this procedure is completed to
customize AccuBoom performance to the specific vehicle and Bogballe spreader.

1.

From the field computer Home screen, touch the Tools Menu icon and touch the AccuBoom icon within the
System submenu.

2.

Enable the “Use Look Ahead Distance” option at the bottom of the screen by touching the box until a check
is displayed.

3.

Touch the Off Look Ahead button and use the up or down arrows to set the off look-ahead value to the
spread distance value determined from the appropriate Bogballe spread chart.

4.

Touch the green check mark to return to the AccuBoom Configuration screen.

5.

Touch the On Look Ahead button and use the up or down arrows to set the on look-ahead value to zero.

Note:

The procedure above will configure the AccuBoom system for general operation with the Bogballe
spreader. To fine tune AccuBoom performance for the specific Bogballe system and the specific
vehicle, adjust the look-ahead values in small increments until the desired performance is
achieved.

See Chapter 9, Using AccuBoom™, for more information on setting up and operating the
AccuBoom feature on the field computer.