Tools Menu

Min PWM. Enter a Min PWM value to set the minimum desired RPM or hydraulic output (zero point or shutoff
point) for a Pulse Width Modulated (PWM) hydraulic control valve.

With the machine’s master switch in the on position, decrease this value until one of the following conditions is
met:

The minimum desired pressure is reached in a liquid system

The value when the belt stops moving in a granular system

PWM Frequency. This value sets the frequency of the pulses that are sent to the PWM valve. The default
value is 122 Hz for Raven valves, or a value specified by the valve manufacturer.

Calibration Settings

The Calibration Settings screen displays calibration values for the selected product and application type.

Touch the corresponding button to enter or modify a calibration value for the selected product node.

Note:

For recommended methods of calculating various calibration values, refer to Appendix A,
Calculating the Calibration Values
.

Meter Cal or Product Density

The flow meter calibration (meter cal) value can be found on the tag attached to the flow meter.

Note:

Copy the information from the tag for future reference as tags may fade or be lost during
operation.

If operating in a granular application mode, the Product Density button replaces the meter cal value. Touch the
Product Density button to enter the measured product density.

Granular Control Mode

Liquid Control Mode