Setup issues, Job issues, Setup issues job issues – Smithco Envizio Pro Installation & Operation Manual User Manual
Page 180

Chapter 11
170
Envizio Pro and Envizio Pro II Installation and Operation Manual
Setup Issues
Job Issues
Red DGPS Status
indicator on the Home
screen
• GPS cable is not
connected
• Check the cable between the GPS receiver and the field
computer.
• No power to the GPS
receiver
• Check power to the GPS receiver.
• Incorrect port setting
• Make sure that the port settings on the field computer and the
GPS receiver are the same.
• Incorrect GPS source
selected
• Verify that the correct GPS Source is selected. (Tools
Menu>GPS menu>Source)
Product node(s) not
detected.
• Wrong control type
selected on the control
interface screen.
• Verify the control type setting is correct for the control system.
(Tools Menu>System menu>Control Interface).
• Node connection issue in
CAN system
• See the CAN Troubleshooting section on page 34 for CAN
troubleshooting information.
Field computer does
not completely power
down
• The orange wire is
connected directly to a 12V
power source
• Do not connect the orange wire to a source of +12VDC.
Vehicle battery
discharges overnight
• CAN nodes are wired
directly to the battery
• Wire the CAN nodes through a relay or switched power
source.
Issue
Possible Cause
Solution
Previous settings
have been lost
• Settings data deleted from
memory
• Review Chapter 7, Tools Menu or Chapter 8, Software
Updates and File Maintenance, for data information.
• Poor CAN connections
• See the CAN Troubleshooting section on page 34 for more
information.
Issue
Possible Cause
Solution
Section numbers do
not turn green
(remain white)
• Boom switches are turned
off
• Turn section and master switches on.
• AccuBoom enabled but
machine not spraying
• Move the machine out of the applied zone.
• CAN is disconnected
• See the CAN Troubleshooting section on page 34 for more
information.
• The section is not set up
properly
• Check the section setup in the Boom Sections screen of the
Vehicle menu.
• Wrong boom master
option selected
• Verify the boom master option setting is correct for the control
system. (Tools Menu>System menu>Control Interface)
• Nodes not completely
programmed
• Check node calibration and ensure all settings have been
completed.
• The section is
disconnected
• Check the connection and wiring to the boom or implement.
AccuBoom with
Raven serial console,
sections will not turn
off
• Console section switches
are in the 'On' position
• Section switches on Raven serial console must be in the 'Off'
position.
Issue
Possible Cause
Solution