beautypg.com

Setup issues, Job issues, Setup issues job issues – Smithco Envizio Pro Installation & Operation Manual User Manual

Page 180

background image

Chapter 11

170

Envizio Pro and Envizio Pro II Installation and Operation Manual

Setup Issues

Job Issues

Red DGPS Status
indicator on the Home
screen

• GPS cable is not

connected

• Check the cable between the GPS receiver and the field

computer.

• No power to the GPS

receiver

• Check power to the GPS receiver.

• Incorrect port setting

• Make sure that the port settings on the field computer and the

GPS receiver are the same.

• Incorrect GPS source

selected

• Verify that the correct GPS Source is selected. (Tools

Menu>GPS menu>Source)

Product node(s) not
detected.

• Wrong control type

selected on the control
interface screen.

• Verify the control type setting is correct for the control system.

(Tools Menu>System menu>Control Interface).

• Node connection issue in

CAN system

• See the CAN Troubleshooting section on page 34 for CAN

troubleshooting information.

Field computer does
not completely power
down

• The orange wire is

connected directly to a 12V
power source

• Do not connect the orange wire to a source of +12VDC.

Vehicle battery
discharges overnight

• CAN nodes are wired

directly to the battery

• Wire the CAN nodes through a relay or switched power

source.

Issue

Possible Cause

Solution

Previous settings
have been lost

• Settings data deleted from

memory

• Review Chapter 7, Tools Menu or Chapter 8, Software

Updates and File Maintenance, for data information.

• Poor CAN connections

• See the CAN Troubleshooting section on page 34 for more

information.

Issue

Possible Cause

Solution

Section numbers do
not turn green
(remain white)

• Boom switches are turned

off

• Turn section and master switches on.

• AccuBoom enabled but

machine not spraying

• Move the machine out of the applied zone.

• CAN is disconnected

• See the CAN Troubleshooting section on page 34 for more

information.

• The section is not set up

properly

• Check the section setup in the Boom Sections screen of the

Vehicle menu.

• Wrong boom master

option selected

• Verify the boom master option setting is correct for the control

system. (Tools Menu>System menu>Control Interface)

• Nodes not completely

programmed

• Check node calibration and ensure all settings have been

completed.

• The section is

disconnected

• Check the connection and wiring to the boom or implement.

AccuBoom with
Raven serial console,
sections will not turn
off

• Console section switches

are in the 'On' position

• Section switches on Raven serial console must be in the 'Off'

position.

Issue

Possible Cause

Solution

This manual is related to the following products: