Chapter 9

152

Envizio Pro and Envizio Pro II Installation and Operation Manual

maneuvering when crossing spray zones. Higher aggressiveness settings will increase the override time for
subsequent AccuBoom section control commands.

To set the AccuBoom aggressiveness from the main screen:

1.

Touch the Tools Menu and select the AccuBoom icon located within the System menu.

2.

Touch the Aggressiveness button.

3.

Select the desired aggressiveness setting to match the operator driving style or requirements.

4.

Touch the accept icon to save the aggressiveness factor setting and return to the AccuBoom Configuration
screen.

Master Pressure

If the product control node is capable of controlling the AccuBoom feature based upon boom pressure, the
Master Pressure button will be displayed on the AccuBoom Configuration screen.

Touch the master pressure button to display the AccuBoom Master Pressure screen and configure the master
pressure feature. This feature allows the field computer to enable or disable AccuBoom control based upon the
liquid pressure at the booms.

Note:

The master pressure feature requires a pressure transducer to monitor the pressure in the main
product line. Contact a local Raven dealer for details or to purchase an optional pressure
transducer. Disable the master pressure feature if a pressure transducer is not installed with the
CANbus system.

On Pressure

Set the pressure at which the field computer will allow the AccuBoom feature to automatically control boom
sections.

Since boom pressure may fluctuate slightly when sections activate, it is recommended to set this value above
the minimum desired boom pressure to ensure adequate pressure to maintain the spray pattern.