beautypg.com

Gasboy 1000 Series FMS Diagnostic Manual User Manual

Page 85

background image

GASBOY Series 1000

5-10

03/07/03

The LCD display prompts you for each field on the key with the field name followed by either
dashes or data. To keep the existing data, press ENTER. To change the data, press the
numbers for the new data and ENTER. If you make a mistake before pressing ENTER,
press CLEAR and the data will be erased and you can start again.

Key types 1 and 2 allow field separators in certain fields. To encode field separators in a
field, press CLEAR twice. Dashes are displayed to represent the field separators. If you
change your mind, press CLEAR again and the display is erased. Press CLEAR again and
you will see the dashes again. You can toggle between a clear display and the dashes with
the CLEAR button. Press ENTER to go on to the next field.

If you have the Supervisor Key Option, you can encode special characters (dots) in the ID
fields of key types 1, 2, or 3 to indicate that the field data will be entered at the keypad. The
method for inserting these special characters varies by key type. For key type 3, press
CLEAR twice. The field is filled with dots. For key types 1 and 2, press CLEAR three times
to display the dots. You can alternate among the clear display and dots by repeatedly
pressing the CLEAR button; key types 1 and 2 also have a field separator character. Press
ENTER to go on to the next field.

When you have entered data for all fields, the LCD displays: ENCODE? 1=YES 0=NO

5.

To encode the key, press 1 and ENTER. If you removed your key before arriving at this step,
you will be prompted, INSERT KEY. If you have a two receptacle system, you must put the
key back into the same receptacle that it was originally in. Once the key is in place, the
display will show WRITING RECEPTACLE X, where X is 1 or 2 (depending on which
receptacle your key is in). When the encoding is complete the display will show ENCODING
COMPLETE
, followed by TURN KEY LEFT,REMOVE.

To terminate without encoding the key, press 0 and ENTER. The LCD displays TURN KEY
LEFT,REMOVE
if your key is still in the receptacle. Turn the key to the left and remove it
and the INSERT KEY prompt reappears. If you have already removed your key, the display
will show INSERT KEY. Insert a key to encode or press ENTER to select a different
diagnostic test.

6.

Turn your key to the left and remove it and the display returns to INSERT KEY.

7.

Insert another key to encode or press ENTER to select a different diagnostic test.

NOTE:

Do not remove your key until you see TURN KEY LEFT,REMOVE. If the key is
removed during the actual encoding process, the LCD displays ABORTED, KEY
REMOVED
and returns to the INSERT KEY prompt. Be sure to re-encode this
key before using it for fueling.