Test 3 - display data on card or key – Gasboy 1000 Series FMS Diagnostic Manual User Manual
Page 81

GASBOY Series 1000
5-6
03/07/03
Test 3 - Display Data on Card or Key
Card Systems
This test reads and displays the information encoded on a card. This test is available only with
card systems. If you have a cardless system and try to run this test, the LCD displays TEST NOT
AVAILABLE.
1.
Enter diagnostic mode as described previously. At the ENTER TEST 0-9 prompt, press 3
and ENTER.
2.
At the ENTER CARD prompt, insert the card for which the information is to be displayed.
3.
At the REMOVE CARD prompt, remove the card from the reader. The display shows the
first four digits encoded on the card.
4.
Press any button, except ENTER to show the next four digits on the card. Continue this until
all digits are read from the card. When the last digits are read, the ENTER CARD prompt
reappears.
5.
To read another card, insert the next card and repeat this procedure from Step 3. To return
to the ENTER TEST 0-9 prompt, press ENTER.
To exit from diagnostic mode, turn off the diagnostic switch at any point.
FleetKey Systems
This test reads and displays the information encoded on a key. This test is available only with
FleetKey systems.
1.
Enter diagnostic mode as described previously. At the ENTER TEST 0-9 prompt, press 3
and ENTER.
2.
At the INSERT KEY prompt, insert and turn the key for which the information is to be
displayed. The display shows the first field encoded on the key (KEY TYPE).
3.
Press any button, except ENTER, to show the next field on the key. (Fields and data longer
than 20 characters scroll across the display the next time you press a key). Continue this
until all fields are read from the key. When the last digits are read, the TURN KEY
LEFT,REMOVE prompt appears.
4.
To read another key, insert the next key and repeat this procedure from Step 2. To return to
the ENTER TEST 0-9 prompt, press ENTER.
To exit from diagnostic mode, turn off the diagnostic switch at any point.