Point of Sale and Shift Change

Disk journal layout

61

03/07/03

Gasboy CFN Series

Transaction detail: tax

(The tax type of transaction detail record is used only by Site Controller software version 2.0C
and above.)

Offset Length Value Type Description
0 1 S A0

checksum

type

(=Sum)

1

3

U0

checksum (on next field through CR/LF)

4

5

U0

record sequence number

9 1 T A0

record

class

(T=Transaction)

10 1

T A0

record

subclass

(T=Tax)

11 2

1 U0

record

revision

level

13 6

U0

site

ID

19 4

I0 transaction

serial

number

23

2

U0

item position in this sale

25

1

S2

item status (0=normal, 1=void)

26 10 C2

tax

amount

36

1

S8

tax type (1-8=normal, 9=exempted)

37 1

U0

[reserved]

38 2

RS

end-of-record

(CR/LF)

-

40

Event

System event

Offset Length Value Type

Description

0 1 S A0

checksum

type

(=Sum)

1

3

U0

checksum (on next field through CR/LF)

4

5

U0

record sequence number

9 1 E A0

record

class

(E=Event)

10 1

H A0

record

subclass

(H=Header)

11 2

1 U0

record

revision

level

13 6

U0

site

ID

19 3

U0

event type (see page Error! Bookmark not defined.)

22 6

D3

date

(yymmdd)

28 4

T2

time

(hhmm)

32

4

U0

shift reference number (if instant-on refusal is set, this

field shows tender and tender subtype)

36 2

U0

shift

number

38 2

U0

clerk

number

40 2

U0

console

number

42

11

C2

amount (if applicable)

53

20

A0

brief description (if instant-on refusal is set, this

field shows transaction number)

73 2

RS

end-of-record

(CR/LF)

-

75

General purpose event

Offset Length Value Type

Description

0

1

S

A0

checksum type (=Sum)

1

3

U0

checksum (on next field through CR/LF)

4 5 U0

record

sequence

number

9

1

E

A0

record class (E=Event)

10

1

G

A0

record subclass (G=General purpose)

11

2

1

U0

record revision level

13 6 U0

site

ID

19

3

U0

event type (always 000)

22 6 D3

date

(yymmdd)

28 4 T2

time

(hhmm)

32

0-221

AV

text (variable length)

32-253 2

RS end-of-record

(CR/LF)

-

255