Avery Dennison SNAP 500 User Manual
Page 84
84
User’s Manual—SNAP™ 500 Gen 1 and Gen 2
Voice Message
Prompt
Description
Internal error. Press
start to continue.
MCB CMD_FRE INDEX ERR
MCB CMD_FSE INDEX ERR
MCB BAD STACK ERROR
MCB KNF FLIT TBL TOO
BIG
MCB KNIFE STATE TOO
BIG
MCB KNIFE STATE TOO
BIG
MCB BEMF MON ST TOO
BIG
MCB STACKR HM ST TOO
BIG
MCB KNF HOME ST TOO
BIG
MCB BEMF CTRL ST TOO
BIG
MCB SHE BATCH Q
OVERFLOW
MCB FVE INDEX ERROR
MCB ERROR #58
MCB ERROR #59
MCB ERROR #60
MCB ERROR #64
MCB ERROR #68
MCB ERROR #69
MCB ERROR #70
MCB ERROR #91
MCB ERROR #95
MCB ERROR #97
MCB ERROR #98
MCB ERROR #99
These are internal software errors. If one of them
occurs, clear the error and continue. If the error
continues to occur, report the error and the
circumstances that cause it to AVERY DENNISON
Service. These errors are caused by errors in the
software and are not caused by hardware failures.
Internal error. Press
start to continue.
OUT OF MEMORY
IMAGER ERROR 919
These are internal errors similar to the ones above.
However, these errors will require power cycling the
printer. If the error continues to occur, report the
error and the circumstances that cause it to AVERY
DENNISON Service.
Knife cycle error.
Increase label length
or select a slower
print speed.
LBL TOO SHORT FOR
SPEED
This error indicates that the label is shorter than the
minimum length for the selected print speed. Refer
to the Printer Specifications for minimum label
lengths. (Minimum label lengths are different for the
Sonic Knife. Refer to the Sonic Knife manual.) To
run and cut the label, you must either make the label
longer or reduce the print speed.
The tape supply roll
is empty
STOCK OUT
This error indicates the tape supply roll is empty. If
the tape supply roll is not empty, make sure the
supply core is firmly held by the arbor clamp.
If this error continues to occur, remove the tape roll
and press the Start button (the Ready light must be
on). The tape arbor should spin counter-clockwise
briefly. If it doesn’t, the motor or MCB is defective. If
it spins and you continue to get the error after re-
installing the tape roll, the MCB is defective.