4.6

Implementation of stop categories

4

Function Description

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-60

Wiring suggestion

Implementation of Category 0 E-STOP, control function with auxiliary

contactors

Fig. 4-19:

Stop Category 0

][Funktion_Stopp_Motorleistung

S1: On

S2: Off

S3: E-STOP

Motor output P

M

Motor circuit brake resistor R

M

Up to 2.5 kW

27

Ω

(20 W) 1000 V

2.5 kW - 5 kW

8.2

Ω

(50 W) 1000 V

or

S1

S2

S3

BTB

M

M

M