3safety, 3 standards – Pilz PMCprotego D.72/000/0/0/2/208-480VAC User Manual
Page 30

3.3
Standards
3
Safety
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
3-8
quency converters and servo amplifiers, which are intended to elim-
inate the risk of these devices causing a fire.
UL 840
UL 840 describes the fulfilment by design of clearance and creepage
distances on electrical equipment and printed circuit boards.
Functional safety standards
EN 61800-5-2:2007 (Adjustable speed electrical power drive systems
– Safety requirements – Functional)
EN ISO 13849-1:2008 (Safety of machinery – Safety-related parts of
control systems)
EN 61508-1:1998 (Functional safety of electrical/electronic/program-
mable electronic safety-related systems – General requirements)
EN 61508-2: 2000 (Functional safety of electrical/electronic/program-
mable electronic safety-related systems – Requirements)
EN 61508-3:1998 (Functional safety of electrical/electronic/program-
mable electronic safety-related systems – Software requirements)
EN 61508-4:1998 (Functional safety of electrical/electronic/program-
mable electronic safety-related systems – Definitions and abbrevia-
tions)
IEC 62061:2005 (Safety of machinery - Functional safety of safety-re-
lated electrical, electronic and programmable electronic control sys-
tems)
The machine or plant manufacturer must check to see whether any ad-
ditional standards or EU directives are applicable for his plant or ma-
chinery.