The safety function STO complies with PL e (Cat. 4) of EN ISO 13849-
1 and SIL CL 3 of EN/IEC 62061.
The relays' wiring must comply with the category or performance level
required for the application. Further information on the safety control
system PNOZmulti is available from Pilz.
Fig. 4-8:
STO, dual-channel with the safety control system PNOZ
mm0p
4.3.4
Analogue inputs
Analogue inputs
4-
][Funktion_Ein_analog_protego_D
Functions:
The servo amplifier has 2 analogue voltage inputs (ANALOG-IN1, AN-
ALOG-IN2) for specifying setpoint values.
Differential inputs, signal range from -10 VDC to +10 VDC.
Resolution (with sign bit): 16 Bit
Parameter setting:
Parameter settings and additional signal processing can be defined us-
ing the PDrive commissioning software. The voltage is scalable in cur-
rent or speed.
Default setting:
– Input ANALOG-IN1: Speed setpoint
– Input ANALOG-IN2: Torque setpoint