Control element

4

Function Description

Parameter setting:

The following can be set in the “Encoder Emulation” window in the com-

missioning software:

Output of SSI signals, "Encoder Emulation" window:

ENCMODE = 10

Clock frequency of the SSI evaluation (1.3

μ

s or 10

μ

s)

Signal sequence in grey format (standard) or binary format

Timing diagram:

Fig. 4-11:

Timing diagram in gray and binary code

Switch over time for data t

v

300 ns

Min. period length T = 600 ns

Timeout t

p

= 1.3

μ

s or 10

μ

s (SSITOUT parameter)

Output |

Δ

U|

I

2 V/20 mA

Input |

Δ

U|

0.3 V

Default count direction: Upwards, facing the motor axis when rotating

clockwise

Revolution

SSIREVOL

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

13

12

11

10

9

8

7

6

5

4

3

2

1

0

12

11

10

9

8

7

6

5

4

3

2

1

0

11

10

9

8

7

6

5

4

3

2

1

0

Position

Bit

15

14 13

12

11

10

9

8

7

6

5

4

3

2

1

0

Clock

Monoflop

Gray

Binär

1

2

3

4

2

31

2

0

G31

G0

T

tv

33

32

tp

This manual is related to the following products: