3 motor holding brake, 6wiring, 6 power element – Pilz PMCprotego D.72/000/0/0/2/208-480VAC User Manual
Page 125

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-17
6.6
Power element
6
Wiring
6.6.3
Motor holding brake
Motor holding brake
6-
][Verdr_Leiterquerschnitte_Verweis
Under “Connection cables”, please note the requirements for the:
Cable cross sections
Insulation material
][Verdr_Motorhaltebremse_protego_D_48_72
Cable length > 25 m
Leakage currents on long cable runs
place a load on the servo amplifier's
output stage.
Wire the motor choke (accessories)
into the motor cable, close to the am-
plifier.
Connect the shielding on both ends.
Connector pin assignment
Connector X9A
Pin
Designation
Description
1
BR+
Brake+
2
BR-
Brake-
Connector pin assignment
Connector X9B
Pin
Designation
Description
1
BR+24V
Supply voltage 24 V for motor holding brake
2
BRGND
Earth
Connection (continued)
PMCprotego
X8
M
PE
U2
V2
W2
PE
U
V
W
3L
X9A
BR-
BR+
1
2
X9B
BRGND
BR+24 V
1
2