3 advanced menu, 7commissioning, 4 leds and keys – Pilz PMCprotego D.72/000/0/0/2/208-480VAC User Manual
Page 191

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-13
7.4
LEDs and keys
7
Commissioning
7.4.3
Advanced menu
Advanced menu
7-
][Inbetrieb_Menu_erweitert
In the advanced menu you can also change numerical values.
Keep the right-hand button pressed down as you switch on the 24 V
supply voltage
Fig. 7-5:
Advanced menu
Status
to
to
to
to
to
to
or
or
or
Station address
Transmission rate
KP (speed control)
Tn (speed control) [ms]
Setpoint offset [mV]
or
Motor type (see motor database)
Brake
Multidrive
Load data from EPROM
Save data to EPROM
ASCII command RSTVAR (resets parameter to default values)
ASCII command M_RESET (recompiles macros)
Serial number: 9-digit number divided into 3 blocks,
position of decimal point indicates the block number