2. Respond to the dialogue box as follows:
– Click on
Yes
if the parameters that have not been considered in the
entry are to be set to default values (recommended when commis-
sioning for the first time).
– Click on
No
if the parameters that have not been considered in the
entry are to remain unchanged (recommended if only the motor
type has been changed).
The parameters are downloaded to the servo amplifier.
After the download, a dialogue box is opened.
3. Click on
Yes
if the parameters in the EEPROM are to saved and the
servo amplifier restarted.
7.2.7
Perform the first test run
Perform the first test run
7-
][Inbetrieb_Testlauf
1. Start the diagnostic tool PScope
In the PDrive commissioning software select
Programs -> PScope
.
A dialogue box appears.
Select
Amplifier-Oscilloscope
as the signal source.
2. Select diagnostic values
Select the values you wish to display in the
Source
field:
–
Channel 1
tab: n_soll, speed setpoint is displayed
–
Channel 2
tab: n_ist, actual speed value is displayed
–
Channel 2
tab: i_ist, actual motor current value is displayed
3. Specify motor setpoints
Set up a reverse mode as an example.
Select the
Reverse mode
function under the
Motor Tuning
tab.
INFORMATION
You can change the signal axis and colour for each channel.