Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-21

6.7

Control element

6

Wiring

6.7

Control element

6700

Control element

6-

6.7.1

Supply voltage 24 VDC

Supply voltage 24 VDC

6-

][Verdr_Leiterquerschnitte_Verweis

Under “Connection cables”, please note the requirements for the:

Cable cross sections

Insulation material

Verdr_Versorgung_Warnung

][Verdr_Versorgung_24_V_protego_D_48_72

][Verdr_Versorgung_24_V_protego_Sicherung

Use the following fuses, depending on the device type.

WARNING!

Electric shock!

Safe electrical isolation must be ensured for the external power

supply that generates the supply voltage. Failure to do so could

result in electric shock. The power supplies must comply with

EN 60950-1, 05/2006, EN 61558-2-6, 11/1997.

Connector pin assignment

Connector X4

Pin

Designation

Description

1

+24 V

Supply voltage + 24 VDC

2

+24 V

Supply voltage + 24 VDC

3

XGND

Earth for supply voltage

4

XGND

Earth for supply voltage

Connection

Connected internally:
Pin 1 and 2 (24 V)
Pin 3 and 4 (XGND)

24 V connection isolated from exter-
nal power supply, e.g. with isolating
transformer

Noise suppression filters integrated
within the servo amplifier

Fuse

Device type

D.48

D.72

Type

Blow-out fuse or similar

8 A

8 A

Fine wire fuse or
circuit breaker

X4

XGND

STO1-STATUS

1

2

3

4

5

6

7

8

STO2-STATUS

STO1-ENABLE

STO2-ENABLE

XGND

+24V

+24V

4

L3

1

PMCprotego

X4

L1

L2

2

+24 V

XGND

PE

+24 V

+24 V

XGND

3