beautypg.com

1 shield connection on the front plate, 3 filters, 6wiring – Pilz PMCprotego D.72/000/0/0/2/208-480VAC User Manual

Page 121: 5 emc-compliant wiring

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-13

6.5

EMC-compliant wiring

6

Wiring

6.5.2.1

Shield connection on the front plate

Shield connection on the front plate

6-

][Verdr_Schirm_Front_D_48_72

6.5.3

Filters

Filters

6-

][EMV_Filter

Noise suppression filters are integrated within the servo amplifier for the

mains voltage and 24 V supply voltage.

These noise suppression filters are used to:

Protect the devices from conducted, high frequency disturbances

(noise immunity)

Remove the outer cable sheath and the braided shield to
the required wire length. Secure the wires with a cable tie.

Remove the outer cable sheath to a length of approx.
30 mm. Be careful not to damage the braided shield.

Strip all the wires and fit end ferrules.

Use the cable ties to attach the cable to the shielding plate
on the side (1) or bottom (2) of the servo amplifier. Press the
cable's braided shield firmly against the shielding plate on
the servo amplifier using a cable tie.

Alternatively you can use the shielded connection termi-
nals (3) (available as an accessory). These hook into the
bottom shielding plate and guarantee optimum contact be-
tween the shield and the shielding plate.

Wire the plug-in terminals as shown in the connection dia-
gram.

The shield on the motor cable is connected to the large
shielding plate using a shielded connection terminal (3).

1

2

3

This manual is related to the following products: