4.4
Expansion cards
4
Function Description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-48
4.4.3.3
Analogue inputs
Analogue inputs
4-
][Funktion_Erw_PosI_O_AI
Functions:
The expansion card PosI/O-AIO has 2 analogue voltage inputs (ANA-
LOG-IN3, ANALOG-IN4) for specifying setpoint values.
Differential inputs, signal range from -10 VDC to +10 VDC.
Resolution (with sign bit): 16 Bit
Parameter setting:
A list of the pre-programmed functions is available in the “Digital I/O”
window of the PDrive commissioning software.
][Funktion_Ein_Aus_Param_neu
If a pre-programmed function has been newly assigned, the data
record must be stored in the servo amplifier's EEPROM and the unit
must be reset (e.g. using the commissioning software).
4.4.3.4
Analogue outputs
Analogue outputs
4-
][Funktion_Erw_PosI_O_AO
Functions:
The expansion card PosI/O-AIO has 2 analogue voltage outputs (AN-
ALOG-OUT1, ANALOG-OUT2). Digital measured values recorded in
the servo amplifier can be output.
Signal range from -10 VDC to +10 VDC.
Resolution (with sign bit): 16 Bit
Parameter setting:
A list of the pre-programmed functions is available in the “Digital I/O”
window of the PDrive commissioning software.
][Funktion_Ein_Aus_Param_neu
If a pre-programmed function has been newly assigned, the data
record must be stored in the servo amplifier's EEPROM and the unit
must be reset (e.g. using the commissioning software).