4.5

Switch on/switch off behaviour

4

Function Description

4.5.2

Fault condition

Fault condition

4-

][Funktion_Ein_Aus_Fehler

The behaviour of the servo amplifier always depends on the current set-

ting of various parameters (e.g. ACTFAULT, VBUSMIN, VEL0, STOP-

MODE, see commissioning software's online help).

The diagram illustrates the start-up procedure and the sequence of the

servo amplifier's internal control system in the event of a failure of one

or more phases of the mains voltage, when the standard parameters are

set.

F16/F19 = Error messages for mains-BTB/input phase

F05 = Error message for undervoltage)

Fig. 4-18:

Switching on and off under fault conditions

24 V

BTB/RTO

L1,L2,L3

Intermediate

circuit

HW-ENABLE

Motor

speed

Output stage

enable

(internal)

Boot-Time

U

F16 / F19

U

U

U

U

n

t

t

t

t

t

t

t

t

U

VEL0

5

Start

Standard mode

Mains error

t

3 % VBUSMIN

F05