beautypg.com

8 • scanning – Pitney Bowes DI950 FastPac Inserter User Manual

Page 162

background image

8-18

SV61311 Rev. E

8 • Scanning

Menu Option

Associated Options/Actions

Mark Location

Settings
NOTE:
This option is

disabled when Content

in Line with Marks is

set to "No" and the

Scan Configuration

contains multi-mark

with fixed first and last

mark.

Allows you to setup various OMR mark-related

measurements:

Top of Page to Frst Mark is the distance from the top of

the page to the first mark.

Total Length of Marks is the length from the top of the

first possible mark to the bottom of the last mark.

Top of Page to Clear Zone is distance from the top of the

page to the beginning of the Clear Zone.

Length of Clear Zone is the distance from the top of the

Clear Zone to the first mark.

Follow the steps below to enter the various mark-related

measurements:
a. Select an option, then use the UP/DOWN arrow keys to

enter the appropriate measurement (in millimeters).

b. Press "Accept" when you are done entering the

measurement.

c. Once all measurements have been entered, select

"Accept" to return to the Scan Settings screen.

NOTE: For more information about determining each of the

above measurements, refer to OMR Specfcatons in this

chapter.

Item Over Count

Quantity

Allows you to select the number of items that cannot be run

normally.
a. Use the UP/DOWN arrow keys to enter the item over

count quantity.

b. Select "Accept" when you are done.
NOTE: At this time, only a single scanned insert can be

added to each mail piece. The scanned insert must be a

Reply Envelope (BRE).

Item Over Count

Action

Allows you to select what will happen to items that exceed

the item over count quantity. Choices include:

Dvert – Select this option if the Scan Configuration does

not have the Divert Sheet (DVS) scan mark, and you

want the system to divert items once the item over count

quantity has been exceeded.

Stop - Select this option if you want the system to stop

processing items once the item over count quantity has

been exceeded.

Use Alternate Envelope – Select this option if the Scan

Configuration does not have the Envelope Select (ES)

scan mark, and you want the system to use an alternate

envelope for items that exceed the item overcount

quantity.

Refer to Scannng Features in this chapter for more

information on dynamic envelope selection and divert sheet

functionality.

Assigning

a Scan

Configuration

to an Existing

Job (continued)