Fdl - performance report message, Generated messages – EXFO FTB-800 Series for FTB-1 User Manual
Page 408

Test Functions
398
FTB-700G/800 Series
FDL - Performance Report Message
FDL - Performance Report Message
Note: FDL PRM is only available for DS1 interface with ESF framing. For Dual RX
test, FDL is only available for the DS1 TX/RX port 1. For NI/CSU Emulation,
only available in the RX direction.
From the Test menu, tap Results, tap the FDL, and
Performance Report Message tab.
Generated Messages
Circuit allows the selection of the circuit type: CI to Network (default)
or Network to CI.
ANSI T1-403 check box when selected allows the generation of a
compliant ANSI T1.403 PRM Message.
Injection
Single sends the selected PRM Message(s) manually.
Continuous generates the selected PRM Message(s) continuously.
Event Count indicates the number of PRM messages sent.
PRM Bit Events allows the activation of the following PRM bit events.
All PRM bit events are disabled by default.
G1: CRC = 1
G2: 1 < CRC 5
G3: 5 < CRC 10
G4: 10 < CRC 100
G5: 100 < CRC 319
G6: CRC 320
SE: Severely errored framing 1
FE: Frame sync. bit error 1
LV: Line code violation event 1
LB: Payload loopback activated
SL: Slip 1
R Bit (Reserved - Default value is 0)
U1: Bit
U2: Bit