EXFO FTB-800 Series for FTB-1 User Manual
Page 114

Test Setup - Test Configurator, Timer, and System
104
FTB-700G/800 Series
BERT
Defect allows to choose on which layer and defect the service
disruption time test will be performed. Choices depend on the
selected test path.
Layer
Signal
Defect
Interface
OTN/SONET/SDH LOS
DSn
LOS, BPV, EXZ
PDH
LOS, CV
OTUk
OTN
AIS, BDI, BEI, BIAE, BIP-8, IAE, LOF, LOM
ODUk
OTN
AIS, OCI, LCK, BDI, BIP-8, BEI
OPUk
OTN
AIS, CSF
Section/RS SONET/SDH
LOF-S/ RS-LOF, B1
Line/MS
SONET/SDH
AIS-L/MS-AIS, RDI-L/MS-RDI, REI-L/MS-REI, B2
STS/AU
Path
SONET/SDH
AIS-P/AU-AIS, LOP-P/AU-LOP, RDI-P/HP-RDI,
REI-P/HP-REI, B3, UNEQ-P/HP-UNEQ
VT/TU
Path
SONET/SDH
AIS-V/TU-AIS, LOP-V/TU-LOP, RDI-V/TU-RDI,
REI-V/LP-REI, BIP-2, UNEQ-V/LP-UNEQ
DS1
DSn
AIS, OOF, RAI, Framing Bit, CRC-6
DS3
DSn
AIS, OOF, Idle, RDI, F-Bit, C-Bit, P-Bit, FEBE
E1
PDH
AIS, CRC-4, E-Bit, LOMF, TS16 AIS, LOF, FAS, RAI, RAI
MF
E4, E3, E2 PDH
AIS, LOF, FAS, RAI
BER
OTN,
SONET/SDH,
DSn/PDH
Pattern Loss, Bit Error