Test Results
348
FTB-700G/800 Series
Summary (EtherSAM)
Start Time
Indicates the date and time the test has been started. The date and time is
reset every time the test is restarted or reset.
Remote unit in use and locked for Dual Test Set
This message indicates that this module is used for Dual Test Set as the
remote module.
Aborted, <reason>
test/subtest has been aborted either manually (Stop) or
automatically from an alarm and the reason why the test has
been aborted is also displayed as follows.
Link down alarm
LOS alarm
Timeout during execution
DTS connection failed
Invalid Configuration (DTS)
Loss of remote connection (DTS)
LOPPS-L Alarm
a
LOPPS-R Alarm
a
LOPPS-L / LOPPS-R Alarm
a
Unresolved addresses
No test enabled
Invalid Burst Configuration
CIR disabled fro all services
Excessive Refill Time
b
Stopped
a.
Available for Dual Test Set in One-Way Latency measurement mode.
b.
An excessive refill occurs when the pre-burst and/or post-burst duration last for more than 2 seconds.