Interface – EXFO FTB-800 Series for FTB-1 User Manual
Page 271

Test Results
NetBlazer
261
Alarms/Errors
Interface
Alarms
LOS (Loss Of Signal)
RX: Absence of an input signal or an all-zeros pattern is received.
Frequency
RX: The received signal frequency meets the standard specifications
(green) or not (red).
For Ethernet 10/100/1000M Electrical, 100M Optical, 1GE Optical, or
10GE LAN/WAN interface/rate, the frequency range is ± 100 ppm.
Interface
Standard Rate Specification
DS1
1544000 ±36.6 ppm
E1
2048000 ±54.6 ppm
E3
34368000 ±24.6 ppm
DS3
44736000 ±24.6 ppm
STS-1e/STM-0e
OC-1/STM-0
51840000 ±20 ppm
E4
139264000 ±19.6 ppm
STS-3e/STM-1e
OC-3/STM-1
155520000 ±20 ppm
OC-12/STM-4 622080000
±20
ppm
OC-48/STM-16
2488320000 ±20 ppm
OTU1
2666057143 ±20 ppm
OC-192/STM-64
9953280000 ±20 ppm
OTU2
10709225316 ±20 ppm
OTU1e
11049107143 ±100 ppm