Test Setup - Test Configurator, Timer, and System
202
FTB-700G/800 Series
Signal (Transport)
Step Size (ppm) allows to set the increment/decrement value (from
0.1 to either 50 or 120 depending on the test configuration) that will be
used when changing the frequency offset with the “+” or “-” button.
RX Frequency
Frequency (GHz) indicates the frequency of the input signal.
Offset (ppm) indicates the frequency offset between the standard rate
specification and the rate at the input signal.
Note: For both Frequency and Offset the following background colors are used.
Max. Negative Offset (ppm) indicates the maximum negative
frequency offset between the standard rate specification and the rate
from the received signal.
OTU1e
± 120 ppm
11049107143 bit/s
OTU2e 11095727848
bit/s
OTU1f 11270089286
bit/s
OTU2f 11317642405
bit/s
a.
The frequency offset range is guaranteed for a source signal at 0 ppm. In the event
that the source signal already has an offset, then the output signal may exhibit an
offset larger than the range specified.
Background color
Description
Green
The frequency is in range.
Red
The frequency is out-of-range. LOC is also
displayed.
Gray
Pending state.
Interface
Frequency Offset
a
Nominal Frequency