1-2

TASC 6100

98-05018

R2

CE & S

TANDARD

V

ERSION

INC / DEC S

WITCH

The Increase/Decrease (INC/DEC) switch (see #3 in
Fig. 1-1) is used, in both the OPERATE and SET-UP
modes, to adjust the values appearing in the display.

B

OOM

S

ECTION

“ON/OFF” I

NDICATORS

The boom section On/Off indicators (see #5 in Fig. 1-
1) indicate which boom sections the operator has
selected. When a boom is turned on, its indicator is lit.
There are a maximum of nine boom sections available.

R

ATE

S

WITCH

The Rate Selector switch (see #6 in Fig. 1-1) is a three
position switch that allows the operator to select
either a pre-selected standard rate, an alternate rate, or
stop the application.

D

ISPLAY

S

ELECTOR

S

WITCH

The Display Selector (see #4, Fig. 1-1) is used to
choose which of the console functions is displayed on
the screen and is available for setting by the operator.

Display Selector - Operate Mode (Liquid)

(See Fig. 1-2)

Speed: The current vehicle speed.

Area: Area Accumulator #1. The total area treated

since the counter was last reset.*

Fan RPM: Not used in liquid mode.

Product Vol: Amount of product aboard the vehicle.

Value counts down as the product is applied and
alarm sounds when 10 % of the full load is left.**