Pressure Sensor:

If the measured amount is more than the indicated

amount, the new cal# should be larger.

If the measured amount is less than the indicated

amount, the new cal# should be smaller.

Flow Meter:

If the measured amount is more than the indicated

amount, the new cal. # should be smaller.

If the measured amount is less than the indicated

amount, the new cal# should be larger.

11. Correct the cal. # in the console. Return the mode

selector to OPERATE. The amount displayed
should now match the amount measured. The flow
sensor is now calibrated.

11a. An alternate method, of correcting the cal. #, at

this point, is to switch back and forth, between
OPERATE/Total Applied and SET-UP/ Total
Applied
, changing the cal. # until the Total
Applied
display, in operate mode, equals the
amount actually dispensed.

12. Write this number down for future reference. This

is the number to use for this specific combination
(material and applicator configuration).

Another method of fine tuning the sensor cal. # is to
weigh the sprayer with a full tank of water, reset the Total
Applied to zero (see page 2-11),
set the GSO speed to 10
MPH, and start spraying while watching the Total
Applied
accumulate. When the Total Applied reaches at
least 100 gallons, re-weigh the sprayer and determine the
actual amount dispensed as compared to that indicated
by the console. Use the method described in step 9 and
10 above to correct the Cal. #.