Err 0
Err 1
Pump C
Err 2
Err 0, Pump C and Cal#:
reenter rate sensor Cal#
(Spreader Constant).
Err 0, Dist. Cal#: reset
distance Cal#.
Err 0, Boom #: reset
boom widths (including
boom width C).
Slow down.
If spreader has an adjust-
able gate height, open the
gate higher and adjust the
spreader constant.
Clean screens (replace
filter elements).
Check Oil cooler for
blockage, check tempera-
tures and oil levels.
Check oil levels and refill
as necessary. Be sure to
use clean oil.
Check hydraulic pump or
motor output and rebuild
or replace as necessary.
Contact MID-TECH if
you see this message on a
TASC 6100 controller.
G
RANULAR
E
RROR
M
ESSAGES
FIRST check the battery connections!!
A required constant is set
to zero.
This can be caused by
poor power connections
at the battery.
Servo valve is fully open,
traveling too fast for
desired application.
Hydraulic strainer
plugged.
Pressure LOW, main
strainer;
pressure HIGH, strainer
upstream from valve.
Hydraulic oil temperature
too high.
Low hydraulic oil.
Worn hydraulic pump or
motor.
Not a diagnostic function
in the TASC 6100.