TeeJet TASC-6100 User Manual
Page 56
![background image](/manuals/713563/56/background.png)
5-4
TASC 6100
98-05018
R2
CE & S
TANDARD
V
ERSION
Hold down the decrease
switch until the alarm stops.
Check for any constants that
may have been set to zero
and re-enter the correct
values. (See Chapter 2)
Hold down the decrease
switch until the display re-
sets to zero.
Establish good ground and
battery connections. This is
the most common fault when
system is acting erratically.
Check and service or replace
the vehicle battery.
Check and service or replace
the vehicle alternator/
voltage regulator.
A momentary appearance,
followed by no other
problems, can be safely
ignored. If messages occur
frequently during operation,
or come on and stay on,
contact your dealer for
further assistance.
Connect pressure sensor.
Recalibrate pressure sensor
to 0 PSI (br).
Err E
OFLO
Err L
Err C, n,
hook (back-
ward 7)
PSI - -
(br - -)
PSI - 0
(br - 0)
Memory error.
This is often the result of a
poor battery connection.
Value to be displayed on
console exceeds the maximum
allowable size.
The vehicle electrical system
voltage has fallen below about
10.0 VDC.
Internal Diagnostics.
Pressure sensor is not con-
nected.
Pressure sensor is detecting a
pressure less than its 0 setting.