Err 3
Pump C

Err 4

Err 5
Pump C

Conveyor is not running.

Conveyor runs but no
rate sensor signals
registered.

Not a diagnostic function
in the TASC 6100.

Application rate is
exceeding the target rate
by 15%. Valve is stuck.

Often this is caused by
loss of power to the
valve.

Turn hydraulic system
ON.

Check for correct opera-
tion of hydraulic valves
feeding the conveyor
motor.

Check clutch if appli-
cable.

Clear blockage in
hydraulic oil lines.

Check Flow control and
Boom connections on the
back of the console.
Secure if loose.

Check continuity of
wiring and connectors.

Test rate sensor and
replace if faulty.

Contact MID-TECH if
you see this message on
an TASC 6100 controller.

Check, at the valve
connector, for the proper
voltages during the OPEN
and CLOSE commands to
the valve. Replace faulty
wiring or driver module
if necessary.

Verify the servo control
valve is responding, fix
faulty wiring or replace
actuator if the problem is
diagnosed as the valve.