Pressure Sensor High/Low Calibration
The pressure sensor's Zero and High Set Point values must
be set to match the readings from your manual pressure
gauge. To do this, follow the procedure below.
Setting The Zero Set Point
A. Set the console to the following positions;
1. Power switch
ON
2. Mode Selector
OPERATE
3. Display Selector switch
PSI/Prime
4. At least one Boom switch
ON
(to release any trapped pressure)
5. Master switch
ON
6. GSO switch
OFF
7. Supply Pump
OFF
8. Zero ground speed (vehicle not moving)
NOTE: Before adjusting the Zero Set Point, make sure
there is no pressure in the boom. It may be necessary to
loosen the diaphragm check valves on the boom to
achieve this.
B. Hold INC./DEC. switch to DEC. until console
reads “PSi 0” (“br 0”).
Setting The High Set Point
A. Set the console to the following positions;
1. Power Switch
ON
2. Mode Selector
OPERATE
3. Display Selector Switch
PSI/Prime
4. Rate Switch
Standard Rate
5. Master Switch
ON
6. Supply Pump
ON
7. Zero ground speed (Vehicle not moving)
B. Hold INC./DEC. switch to INC. for about 3
seconds. Display will read "OPEN". Release the INC
as soon as the “OPEN” message appears. Slowly
increase the engine RPM to adjust the pressure
reading, on the pressure gauge, to a maximum of no
A-7
MT 1000
MPH / KPH
A-8
A-6
MT 1000
MPH / KPH
A-7
MASTER
ON
OFF
MI
A-5
DISPLAY SELECTOR
Speed
Area
Impl. Width
Distance
Test
Speed
PSI/Prime
Total Applied
Application Rate
OFF
SET- UP
DEC.
ON
OPERATE
INC.
Scan
Product Vol.
Fan RPM
BOOMS
1 2 3 4 5 6 7 8 9
% Rate
A-1
A-2
A-3
B
Alt.-Rate
Standard Rate
OFF
A-4
BOOM CONTROL SWITCHES
MASTER
ON
OFF
OFF
GSO
AUTO
MIDWEST TECHNOLOGIES, INC.
MID-TECH
®
A-4
A-5
A-6
DISPLAY SELECTOR
Speed
Area
Impl. Width
Distance
Test
Speed
PSI/Prime
Total Applied
Application Rate
OFF
SET- UP
DEC.
ON
OPERATE
INC.
Scan
Product Vol.
Fan RPM
BOOMS
1
2 3 4 5 6 7 8 9
% Rate
A-1
A-2
A-3
B
A-4