change in the target rate). For example, with the applica-
tion rate set to 10.0 gallons per acre, a single actuation of
the INC. switch causes the system to control flow at the
rate of 12.0 gallons per acre (10.0 + 20% = 12.0).

A. Set the console switches to the following positions:

1. Power

ON

2. Mode Selector

SET-UP

3. Display Selector

% Rate

The display shows the current % change value.

B. Use the INC./DEC. switch to set this number to the

desired % change value.

S

ETTING

B

OOM

W

IDTHS

T

he MID-TECH control console is designed to
automatically compensate for changes in the swath
width, caused by turning boom sections on or off.

To accurately respond to changes in swath width, the
console must know the length of each boom section. Use
the following procedure to set boom section widths.

A. Set the console to the following positions;

1. Power

ON

2. Mode Selector

SET- UP

3. Display Selector

Impl. Width

4. Boom switches

OFF

(or Master switch)

The display cycles through each boom position (1
through 9) and displays its current width in inches
(meters).

B. As each boom position appears on the display, use

the INC./DEC. switch to set the display to the
number of inches (meters) covered by that boom.
Repeat for each section.

C. Set all unused boom sections to a width of zero “0”

inches (meters). This insures that accidentally
turning a boom switch ON doesn’t affect the control
console. (An ERROR 0 Boom # will then result if an
unused boom gets accidentally turned on)

DISPLAY SELECTOR

Speed

Area

Impl. Width

Distance

Test

Speed

PSI/Prime

Total Applied

Application Rate

OFF

SET- UP

DEC.

ON

OPERATE

INC.

Scan

Product Vol.

Fan RPM

BOOMS

1 2 3 4 5 6 7 8 9

% Rate

A-1

A-2

A-3

B

DISPLAY SELECTOR

Speed

Area

Impl. Width

Distance

Test

Speed

PSI/Prime

Total Applied

Application Rate

OFF

SET- UP

DEC.

ON

OPERATE

INC.

Scan

Product Vol.

Fan RPM

BOOMS

1 2 3 4 5 6 7 8 9

% Rate

A-1

A-2

A-3

B, C, D, E

E

MASTER

ON

OFF

MI

A-4

E